CLICK HERE TO DOWNLOAD PRINTABLE/EDITABLE EXCEL VERSION
DFIRSTTM CO-ORDINATION CHECKLIST - MN
PRIOR TO EXERCISE
ACTION/EVENT UNIT UNIT's HIGHER HQ DFIRST MSM REMARKS  
Identify & schedule Annual Training DFIRST requirements. X     During Camp Ripley AT scheduling conference. (Usually January of each year.)
Identify & schedule IDT DFIRST requirements. X     30 days in advance.
Identify general Area of Operations (AO) and general concept of training. Identify special requirements. X     At time of scheduling.
Coordinate movement of base station thru DOL.     X Minimum 30 days in advance. (Alternate is FSB.)
Provide information briefing, conduct coordination visit to unit trainers and participants.     X As required.
Provide OPLAN with overlay. X X   5 days before STARTEX. (Provided to the Operators during operator course is optimal.)
DFIRST operators/installers attend 16 hour course. X     Number of operators/installers and training time are variable based upon mission and equipment.
Conduct DFIRST operator training.     X  
Perform map and ground coverage surveys of AO.     X  
Identify communications requirements: Hardware and SOI. X   X  
Set up base station and relay at training area. X   X MSM with operator assistance. Relay moved to site by unit.
Install DFIRST instrumentation. X   X Vehicle crews assisted by operator/installers and supervised by MSM.
Provide & pre-position generator at site.(15 KW preferred, 10 KW acceptable.) X     24 hours before STARTEX and operationally pre-checked.
DURING EXERCISE
ACTION/EVENT UNIT UNIT's HIGHER HQ DFIRST MSM REMARKS  
Operate DFIRST base station control panel and tactical communications. X     Operator. DMSM assisted. Operator knows unit training objectives and OPLAN.
Conduct After Action Reviews (AARs.) X     O/C conducted, MSM assisted.
Maintain generator fuel site IAW training site SOP. X      
Daily fuel and PMCS generator.     X  
Troubleshoot and keep system operational.     X  
Provide Take Home Package.     X ENDEX.
AFTER EXERCISE
ACTION/EVENT UNIT UNIT's HIGHER HQ DFIRST MSM REMARKS  
Recover communication equipment. X     Operator, MSM assisted.
Recover generator and fuel point materials. X     Operator, MSM assisted.
Un-install, clean, inventory & turn in DFIRST instrumentation. X   X Miles warehouse. 
Recover relay trailer. X   X  
Prepare base station for movement.     X Operator and MSM.
Recover base station.     X Coordinate with DOL.